Related Experiment Video
Updated: May 11, 2025

A Simple and Inexpensive Method for Determining Cold Sensitivity and Adaptation in Mice
Published on: March 17, 2015
Ultrasensitive Room-Temperature NO2 Gas Sensor Based on MXene-Cu2O Composites
Wenbin Ren1, Jinfeng Luan1, Liang Yin1
1School of Physics and Electrical Engineering, Linyi University, Linyi, 276000, China.
Abstract:
The development of real-time trace-level NO2 quantification platforms that can be operated at room temperature constitutes a critical advancement for occupational safety and public health monitoring systems. This study demonstrates a room-temperature NO2 sensor using MXene-Cu2O composites prepared via a hydrothermal method. Systematic evaluation of MXene-introduced effects identified the 0.84 wt % MXene-Cu2O composite as optimal, exhibiting 4-fold enhanced sensitivity and shorter response (55 s)/recovery (35 s) time compared to pure Cu2O. Additionally, the sensor exhibits a low detection limit (10 ppb), high selectivity, great reversibility, and long-term stability. The enhanced sensing performance originates from precisely engineered interfacial architectures between MXene and Cu2O, which effectively adjust the charge-transfer behavior through the conduction tunnel in the sensing material. Furthermore, oxygen vacancy engineering creates defect-mediated adsorption centers that promote selective NO2 chemisorption through charge polarization effects. This research offers a novel strategy for designing optimized structures to enhance the sensitivity of MOS-based materials for NO2 gas detection.
More Related Videos
09:01High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...