Related Experiment Video
Updated: May 11, 2025

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Validation of magnetic resonance imaging-derived venous oxygen saturation and oxygen consumption measurements during
Rachel J Skow1, Stephen J Foulkes1,2, Hendrik Mugele3
1Integrative Cardiovascular Exercise Physiology and Rehabilitation Lab, Faculty of Nursing, College of Health Sciences, University of Alberta, Edmonton, Alberta, Canada.
Abstract:
Accurate measurement of venous oxygen saturation ([Formula: see text]) is fundamental for quantifying oxygen consumption (V̇o2) and its Fick determinants. This study evaluated the validity of a novel magnetic resonance imaging (MRI) approach using susceptometry-based oximetry (SBO) to noninvasively measure [Formula: see text] during exercise. First, [Formula: see text] was measured from an antecubital vein in 14 adults (26 ± 5 yr; 8 males) via portable blood analyzer (iSTAT) at rest and during two 5-min bouts of rhythmic handgrip exercise at 30% of maximum voluntary contraction, with temporally matched SBO measures of [Formula: see text] during an identical in-scanner exercise protocol. Separately, 21 adults (27 ± 6 yr; 8 males) completed incremental step ergometry exercise with simultaneous pulmonary V̇o2 measurement (indirect calorimetry) and MRI-derived V̇o2 from the Fick determinants (MRIFick), including inferior vena cava [Formula: see text] (SBO) and cardiac output (cardiac MRI). Agreement between methods was assessed by interclass correlation coefficients (ICCs), linear regression, and Bland-Altman plots. There was good to excellent agreement between iSTAT and SBO [Formula: see text] for arm exercise (ICC: 0.86, 95% CI: 0.71-0.93, P < 0.01; mean bias: +5.2%). Test-retest reliability demonstrated excellent agreement for [Formula: see text] measures between trials using iSTAT (ICC: 0.97; 95% CI: 0.93-0.96, P < 0.01; mean bias: -2.7%) and SBO (ICC: 0.90, 95% CI: 0.80-0.95, P < 0.01; mean bias: -0.3%), V̇o2 calculated from MRIFick demonstrated excellent agreement with pulmonary V̇o2 (ICC: 0.98, 95% CI: 0.97-0.99, P < 0.01; mean bias: +0.10 L/min). MRI-SBO-derived [Formula: see text] measurements demonstrated excellent reliability and strong agreement with both venous measures and respiratory gas analysis, validating this technique across a wide range of [Formula: see text] values during exercise.NEW & NOTEWORTHY Noninvasive MRI susceptometry-based [Formula: see text] measurements demonstrated excellent repeatability and validity against established direct blood sampling during localized handgrip exercise. The technique's accuracy for determining V̇o2 during step ergometer exercise was validated through strong agreement between combined cardiac MRI and susceptometry-based Fick calculations and reference pulmonary measures, establishing this method as a reliable tool for noninvasive assessment of oxygen uptake and its Fick determinants across varying exercise intensities.
More Related Videos
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.