Purpose:
To evaluate the safety and efficacy of veno-arteriovenous extracorporeal membrane oxygenation (V-AV ECMO) with a secondary centrifugal pump to control blood flow in return pathways as an alternative to the conventional Hoffman clamp.
Materials And Methods:
We conducted a retrospective review of all adult patients who underwent V-AV ECMO in our hospital from January 1, 2022, to December 31, 2023. Data, including demographic characteristics, comorbidities, and ECMO-specific information, were systematically extracted from electronic medical records.
Results:
Five patients, three (60 %) of whom were male, underwent V-AV ECMO. Four patients were initially placed on veno-venous extracorporeal membrane oxygenation (V-V ECMO), and one was placed on veno-arterial extracorporeal membrane oxygenation (V-A ECMO). The mean duration of V-AV ECMO support was 14.4 ± 11.4 days. Ventilator support was reduced, and fewer vasoactive drugs were administrated. Hemoglobin and platelets tended to decrease in all five patients, but D-dimer did not increase. No patients experienced active bleeding, and one patient developed oxygenator thrombosis. Two patients survived to discharge.
Conclusion:
V-AV ECMO using a secondary centrifugal pump is feasible and likely safe without increasing the risk of ECMO-related complications such as hemolysis, thrombocytopenia, blood clot formation, or clotting factor consumption. Future prospective studies are warranted to validate these findings and optimize ECMO management protocols.
More Related Videos
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Hemodialysis II: Procedure and Complications