Published on: September 18, 2012
[Measurement of radial artery diameter by optical coherence tomography via distal radial access]
1Department of Cardiology, Beijing Luhe Hospital, Capital Medical University, Beijing 101100, China.
Insights
Optical coherence tomography (OCT) measured the radial artery (RA) diameter, finding it averages 3.13 mm. Male patients had significantly larger RA diameters than female patients, with gender being a key related factor.
Area of Science:
- Cardiovascular Imaging
- Vascular Biology
- Interventional Cardiology
Abstract:
Objective: To measure the radial artery (RA) diameter and explore its related factors by using optical coherence tomography (OCT). Methods: This was a cross-sectional study conducted in Cardiac Care Unit of Beijing Luhe Hospital, Capital Medical University. Patients who underwent first-ever right forearm access and OCT guided coronary intervention via right distal RA, and measurement of the whole portion of RA diameter with OCT in our center between January 2021 to December 2021 were enrolled. Following the coronary intervention, OCT was used to assess the entire RA. The RA diameter was measured from the RA ostium to 2 cm above the radial styloid process, with a 1 mm interval. Multiple linear regression analysis was performed to determine the factors related the RA diameter. Results: The study enrolled 124 patients with an age of (61.6±12.6) years, of whom 98 (79%) were male. The total length of the RA was (19.5±1.8) cm, for males (20.2±1.3) cm and females (17.2±1.2) cm. The average RA diameter was (3.13±0.50) mm, and the RA diameter at 2 to 5 cm above the radial styloid process was (2.98±0.53) mm. The average RA diameter was significantly larger for male patients than for female patients ((3.21±0.50) mm vs. (2.84±0.37) mm, P<0.001). Multiple linear regression analysis indicated that gender was significantly associated with RA diameter (P=0.019). Conclusions: The average RA diameter measured by OCT is (3.13±0.50) mm, (2.98±0.53) mm at 2 to 5 cm above the radial styloid process. Gender is identified as a factor related to the RA diameter.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)