Related Experiment Video
Updated: May 10, 2025

A Mass Spectrometry-Based Proteomics Approach for Global and High-Confidence Protein R-Methylation Analysis
Published on: April 28, 2022
Buffer 4-Ethylmorpholinium/Acetate: Exploring a New Alternative Buffer for Native Mass Spectrometry
Darya Hadavi1, Che Yee Ng1, Yuandi Zhao1
1Maastricht Multi Modal Molecular Imaging (M4i) Institute, Division of Imaging Mass Spectrometry (IMS), Maastricht University, Maastricht, The Netherlands.
Rationale:
To perform native mass spectrometry (MS) studies, there are a limited number of volatile and electrospray ionization (ESI)-MS compatible solutions, such as ammonium bicarbonate and ammonium acetate (AA). These solutions could induce the unfolding of proteins due to the formation of CO2 bubbles or induced acidification during ESI. Hence, it was important to introduce a buffer suitable to preserve the native form of proteins while simulating physiological conditions.
Methods:
The 4-ethylmorpholinium/acetate (4EM/A) buffer was compared to AA for the analysis of proteins and protein complexes with mass ranges from 5 to 103 kDa and isoelectric points (pI) between 3 and 11. The evaluations were conducted by comparing the native-MS profiles, CCS values, arrival time distributions (ATDs), and proteins bioactivities. The human cardiac troponin complex (cTn complex) and its subunit cardiac troponin T (cTnT) were analyzed as proof of the applicability of this buffer for challenging proteins and protein complexes.
Results:
4EM/A led to lower charge states compared to AA, supporting the likelihood of preserving protein folding during nano-ESI and in a high vacuum environment of MS. Ion mobility measurements revealed that proteins in 4EM/A exhibit a lower degree of conformational variation compared to AA, suggesting enhanced conformational stability and potential retention of natural-like compactness. Additionally, testing the impact of 4EM/A on bioactivity, lysozyme showed increased biological activity in 4EM/A relative to AA, highlighting the buffer's potential for real-time assessment of protein interaction kinetics and bioactivity. The 4EM/A buffer enabled native-MS analysis of cTnT for the first time.
Conclusion:
We introduced 4EM/A, with pKa of 7.72/4.76, as a promising buffer for native-MS studies to maintain protein and protein complex bioactivity and conformational integrity.
More Related Videos
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
10:01Combining Chemical Cross-linking and Mass Spectrometry of Intact Protein Complexes to Study the Architecture of Multi-subunit Protein Assemblies
Published on: November 28, 2017
Related Concept Videos
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example,...
Mass Spectrometry: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing...
Mass Spectrometry of Amines
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...
Mass Spectrometers