Systolic Pressure and Pulse Rate Range Performance Comparison of Seven Non-Invasive Blood Pressure Monitors
John Beard1, Karim Pichard1, Jonah E Attebery1
1GE Healthcare, Chicago, IL, USA.
Purpose:
To evaluate blood pressure (BP) and pulse rate (PR) measurement range and determination time of selected non-invasive blood pressure (NIBP) monitors.
Patients And Methods:
Seven oscillometric NIBP monitors underwent laboratory-based simulations of high and low BP and PR values to determine the outer bounds that each monitor could measure. Reliability was determined by devices' ability to detect simulation signals of chosen BP/PR values. Determination times were analyzed using One-Way ANOVA followed by post-hoc Tukey honestly significant difference.
Results:
All monitors reliably reported 50-180 mmHg and 80-140 bpm simulations, except Connex which provided the narrowest ranges (only reliable at 140 and 230 bpm; 50-180 mmHg). B125 and Efficia CM120 had the widest ranges for PR (30-240 bpm and 30-220 bpm, respectively) and systolic BP (30-250 mmHg for both). Connex presented the quickest mean determination time (19.23s), followed by B125 (24.14s).
Conclusion:
NIBP monitor performances varied considerably outside mid-range BP/PR and there were significant differences across determination times. NIBP devices that strike a balance between range and speed may provide the greatest clinical utility.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: