Related Experiment Video
Updated: May 10, 2025

Author Spotlight: Unveiling the Potential of TUBE Technique in Spinal Surgery
Published on: November 17, 2023
Basivertebral Nerve Ablation in the Setting of Existing Fusion Hardware Case Report
Rhett Layman1, Frankie Prologo2, Mamerhi Okor3
1Department of Radiology, University of Alabama at Birmingham, Birmingham, AL.
Background:
Chronic low back pain (LBP) is a widespread disease particularly as the population continues to age. The most common type of chronic LBP is axial LBP caused by disc degeneration leading to vertebrogenic back pain. Recently, the concept of vertebrogenic LBP has become more mainstream as has its treatment, basivertebral nerve ablation (BVNA). Herein, we report a case where BVNA was performed in the setting of existing hardware at the treatment levels.
Case Report:
Sixty-eight-year-old woman with chronic LBP status post anterior L5/S1 instrumented fusion presents with persistent chronic LBP centralized to L5/S1. Preoperative imaging demonstrates increased signal on bone scan at L5/S1 and BVNA was performed adjacent to the screws, resulting in significant relief of LBP and without complication.
Conclusions:
BVNA is feasible to perform at levels where existing spine hardware is present.