Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Aliasing01:18

Aliasing

461
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
461
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

1.5K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.5K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

1.1K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.1K
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

1.6K
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
1.6K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

512
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
512
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

1.8K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Anaesthesia practitioners in the UK: the high road, not yet taken.

European journal of anaesthesiology·2006
Same author

Awareness and different forms of memory in trauma anaesthesia.

Current opinion in anaesthesiology·2006
Same author

Bispectral index-guided administration of anaesthesia: comparison between remifentanil/propofol and remifentanil/isoflurane.

European journal of anaesthesiology·2003
Same author

Comparison of the hemodynamic effects of milrinone with dobutamine in patients after cardiac surgery.

Journal of cardiothoracic and vascular anesthesia·2001
Same author

The effect of bispectral index monitoring on anesthetic use and recovery in children anesthetized with sevoflurane in nitrous oxide.

Anesthesia and analgesia·2001
Same author

Clinical impact of hypnotic-titration guidelines based on EEG bispectral index (BIS) monitoring during routine anesthetic care.

Journal of clinical anesthesia·2000
Same journal

Pulmonary artery catheters or central venous catheters for cardiac surgery: the PUMA Pilot randomised clinical trial.

Anaesthesia·2026
Same journal

Opioid-free vs. opioid-inclusive anaesthesia with or without regional anaesthesia for postoperative pain.

Anaesthesia·2026
Same journal

Optimal dose of intra-operative dexmedetomidine for postoperative delirium prevention: a reply.

Anaesthesia·2026
Same journal

Optimal dose of intra-operative dexmedetomidine for postoperative delirium prevention.

Anaesthesia·2026
Same journal

Pain control or brain protection with esketamine: a reply.

Anaesthesia·2026
Same journal

A step forward for patient-centred fasting guidelines: a reply.

Anaesthesia·2026
See all related articles

Related Experiment Videos

Unexpected artefact during spectral edge analysis

P S Withington, P S Sebel, H G Rogers

    Anaesthesia
    |July 1, 1985
    PubMed
    Summary

    No abstract available in PubMed .