Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Comparison of PET/CT using 68Ga-NOTA-Exendin-4 with 68Ga-DOTATATE, 18F-FDG, and conventional imaging in the
Haonan Yu1, Xiangyuan Bao1,2, Yian Gu3
1Department of PET/CT Diagnostic, Tianjin Medical University General Hospital, Tianjin, 300052, China.
Purpose:
Accurate preoperative localization is particularly important for surgical treatment of insulinomas. Current imaging methods, including 18F-FDG (FDG) PET/CT, 68Ga-DOTATATE (TATE) PET/CT, CE-CT, and CE-MRI, have limitations. This prospective study provides a direct comparison of 68Ga-NOTA-Exendin-4 (Ex4) PET/CT with other imaging techniques.
Method:
47 patients with biochemically proven endogenous hyperinsulinemic hypoglycemia underwent Ex4 PET/CT and other imaging methods. Sensitivity and accuracy of all imaging procedures for localizing insulinoma were calculated at the patient level and lesion level. Both clinical (>10 years experience) and junior (< 2 years experience) nuclear medicine physician readings were used to assess the diagnostic efficacy. We compared the SUVmax and tumor-to-background ratio (TBR) of three tracers and analyzed the values with Ki-67, maximum tumor diameter, and glucose metabolism indicators.
Results:
In patient level, the sensitivity and accuracy of Ex4 PET/CT (94.11% and 95.74%) were higher than TATE PET/CT (70.59%, p = 0.026; 78.72%, p = 0.030), FDG PET/CT (50.00%, p < 0.001; 63.83%, p < 0.001), CE-CT (77.77%, p = 0.135; 72.22%, p = 0.007), and CE-MRI (63.64%, p = 0.135; 43.75%, p < 0.001), respectively. Interobserver agreement was higher for Ex4 PET/CT than TATE PET/CT and FDG PET/CT (Cohen κ, 0.839 vs. 0.707 and 0.784, respectively). SUVmax and TBR of Ex4 and TATE PET/CT were significantly higher than FDG PET/CT (p < 0.01). Negative correlations of tumor Ki-67 with TATE PET/CT were observed with SUVmax (r = -0.637, p < 0.001). SUVmax and TBR of three molecular imaging methods had positive correlations with the maximum tumor diameter (p < 0.05), except TBR of FDG PET/CT. Semi-quantitative values of the three tracers showed no correlation with the lowest blood glucose level, corresponding insulin, and C-peptide level. TBR of TATE PET/CT showed a positive correlation with C-peptide (r = 0.393, p = 0.043).
Conclusion:
Ex4 PET/CT showed superior characteristics in localization compared to routine imaging modalities in benign insulinomas. Ex4 PET/CT demonstrates better imaging quality and interpretability than FDG PET/CT and TATE PET/CT. Combined Ex4 and TATE PET/CT could provide a comprehensive evaluation/localization of insulinoma.
Trial Registration:
The trial was retrospectively registered at ClinitalTrial.gov (NCT06690957 and NCT06725693) on November 14, 2024 and December 5, 2024.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...