Measuring Nitrite and Nitrate in Rain and River Water Samples Using a Portable Ion Chromatograph in Step-gradient
Yonglin Mai1, Kurt Debruille1, Ibraam Mikhail1
1Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia.
Abstract:
With the increasing environmental pollution issues, there is a growing need for sensitive and real-time monitoring of pollutants. Nitrite and nitrate are common nutrients that are related to water quality. This study aims to enhance nitrate and nitrite detection capabilities using a portable ion chromatography-based nutrient analyzer, Aquamonitrix. By optimizing it for ultra-low detection limits (LODs), we address challenges in environmental water quality assessment in Tasmania, Australia. Using step-gradient mode with a stereolithography three-dimensional printed flow cell with a 5 cm optical path length, a 300 µL injection loop, and 60 mM KOH as eluent, LODs of 0.004 µg/mL for nitrite and 0.023 µg/mL for nitrate were achieved. Further improving to 0.008 µg/mL for nitrate with a 10 cm optical path length flow cell and 120 mM NaCl as eluent. A repeatability assessment over 84 automatic runs showed a relative standard deviation under 1.42% for peak area and 0.49% for retention time. The system demonstrated tolerance to salinity, handling up to 5 parts per thousand in artificial seawater. Comparative analysis of environmental samples revealed that nitrate levels in Tasmanian rainwater were five times lower than in Ireland. An average concentration of 2.08 µg/mL nitrate was found in Tamar River samples, aligning with local commercial lab data. Real-time, on-site analysis along the Derwent River detected an average nitrate concentration of 0.17 µg/mL. Validation against conventional standard ion chromatography showed no significant differences (p > 0.05), underscoring Aquamonitrix's robustness for field-based water quality monitoring. A 5-day deployment of Aquamonitrix further demonstrated the system's reliability under significant temperature fluctuations between day and night.
More Related Videos
Related Concept Videos
Precipitation Titration Curve: Analysis
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-II