Related Experiment Video
Updated: Jul 22, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Use of controlled nail dynamization technique for femoral shaft hypertrophic nonunion
Qian Wu1, Qi Wang1, XueCheng Sun1
1Department of Orthopedics and Trauma Weifang People's Hospital, Shandong Second Medical University, Weifang, Shandong, China.
Background:
Femoral nonunion after intramedullary nailing (IMN) of a diaphyseal long bone fracture is a severe complication that requires effective management. The IMN dynamization has been used to treat hypertrophic nonunions previously. However, routine nail dynamization has only a low success rate and the risk of limb shortening.
Methods:
Two patients with femoral shaft fracture hypertrophic nonunion at 4 or 5 months after intramedullary nailing were treated with the therapeutic paradigm named "controlled nail dynamization". In this paradigm, the interlocking nails are removed but the dynamic hole nails are retained. At the same time, four Poller screws were used to limit the movement of the intramedullary nail in the coronal and sagittal planes. The intramedullary nail can only generate compressive stress along the axial direction of the femoral shaft, thereby promoting fracture healing. So this technique was named "controlled nail dynamization".
Results:
Here, we describe two cases of delayed healing of the femoral diaphysis, which were successfully treated through controlled nail dynamization. Followed up for more than 12 months. Bone union was achieved in both patients, and there were no complications such as nonunion and internal fixation failure.
Conclusion:
The controlled nail dynamization is feasible for safe and effective treatment for femoral shaft hypertrophic nonunion.