Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Single-element ultrasound system for high-resolution jugular venous pulse contour detection
Navya Rose George1, P M Nabeel2,3, Kiran V Raj2,3
1Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India. navya_george@smail.iitm.ac.in.
None:
Jugular venous pulse (JVP) waveform contour is directly linked to right atrial hemodynamics and is a potential tool for diagnosing various cardiovascular diseases. The reference standard, central venous line catheterization, while precise, is restricted to critical care units owing to the necessity for surgical procedures and specialized operator skills. Conventional ultrasound imaging systems can reliably measure jugular venous vessel dynamics but are hindered by low operational frame rates, large form factors, and the requirement for trained operators. In this study, we propose a portable system using single-element ultrasound technology for reliable JVP waveform acquisition and methods for quantifying the JVP contour features. The performance of the system and method was validated against a reference ultrasound imaging system in a preclinical study on 65 asymptomatic volunteers (27 female). Operating at an acquisition rate of 250 Hz, the system reliably captures JVP waveforms with a temporal resolution of 4 ms. The maximum and minimum jugular venous diameter measurements showed a statistically significant and strong correlation with the reference measurements (r = 0.93 and r = 0.86, respectively, p < 0.001). The devised algorithms effectively segmented JVP cycles and analyzed their contour features with a sensitivity and specificity of 92%. These results provide preliminary evidence for the potential use of the developed system for high-fidelity JVP waveform acquisition and pulse contour feature assessment. The ability to accurately evaluate the JVP contour characteristics can provide insights into right atrial hemodynamics, potentially facilitating the early detection and monitoring of vascular anomalies.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: