Related Experiment Video
Updated: May 14, 2025

Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Selective and sensitive detection of CO2 using phosphorescent iridium(III) complexes containing 1,10-phenanthroline
Xiaoxue Liu1, Xi Chu1, Chenghao Li1
1School of Chemical Engineering and Technology, Hebei University of Technology, Tianjin, 300401, China. hyli@hebut.edu.cn.
Abstract:
Based on the neutral ligands of 2-phenyl-1H-imidazo[4,5-f][1,10]phenanthroline (pip) and 2-(4-(trifluoromethylphenyl)-1H-imidazo[4,5-f][1,10]phenanthroline) (tfpip), iridium(III) complexes [(F4ppy)2Ir(pip)](PF6) (1, F4ppy = 2-(4-fluorophenyl)pyridine), [(F4piq)2Ir(pip)](PF6) (2, F4piq = 3-(4-fluorophenyl)isoquinoline), [(F4ppy)2Ir(tfpip)] (PF6) (3), [(F4piq)2Ir(tfpip)](PF6) (4), [(F3,5ppy)2Ir(pip)](PF6) (5, F3,5ppy = 2-(3,5-difluorophenyl)pyridine), [(F3,5piq)2Ir(pip)](PF6) (6, F3,5piq = 3-(3,5-difluorophenyl)isoquinoline), [(F3,5ppy)2Ir(tfpip)](PF6) (7) and [(F3,5piq)2Ir(tfpip)](PF6) (8) were synthesized and characterized. Complexes 1-8 exhibited yellow-green and red luminescence (λ = 528-588 nm) in acetonitrile solution. The photoluminescence quantum yields (PLQYs) of complexes 1-8 ranged from 0.44 to 0.80, and complex 7 with yellow-green emission had the best PLQY of 0.80. An electrochemical study and density functional theory (DFT) calculations showed that the luminescence characteristics of the complexes are mainly controlled through the modification of cyclometalated ligands. Upon addition of CH3COO- to the solution of complexes 1 and 5, the luminescence intensity of 1 and 5 was quenched by 80% and 91%. After bubbling CO2 gas into the solution of iridium complexes containing CH3COO-, complexes 1 and 5 both showed turn-on phosphorescence responses with high sensitivity, excellent selectivity, good reversibility and a low detection limit as low as 22.8 μM.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

