Related Experiment Video
Updated: May 10, 2025

Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
High-Reproducibility and -Stability All-Solid-Contact Nitrate Ion-Selective Electrode with CoWSe2 as Solid Contact
Yanhong Li1, Yunzhe Pan1, Yihan Xing1
1School of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, P. R. China.
None:
The monitoring of nitrate ions is of great significance for human health, agricultural development, and environmental protection. All-solid-state nitrate ion-selective electrodes (ASS-NO3--ISEs), as an important NO3- analysis method, still have two challenges of poor stability and reproducibility due to the ill-defined phase boundary between the solid-contact (SC) layer and the ion-selective membrane (ISM). In this work, a novel strategy for constructing the ASS-NO3--ISEs based on CoWO4, CoWS4, CoWSe2, or CoSe2 as SC layers was reported for improving the stability and reproducibility. The result shows that the developed CoWSe2-based NO3--ISE exhibits a good Nernstian response slope of -61.9 ± 0.4 mV dec-1 in the activity range from 1.0 × 10-6 to 7.5 × 10-2 M and a detection limit of 1.0 × 10-6 M. A good long-term stability (as low as 2.3 ± 0.4 μV h-1) of the CoWSe2-based NO3--ISE is the primary reason for the high redox capacitance of the ternary selenide. Experimental results show a surprisingly good reproducibility of approximately 0.5 mV for five individual ASS-NO3--ISEs. Notably, electrochemical experiments and scanning electron microscopy mapping tests are used to predict the ion-electron transduction mechanism in which the lipophilic anion (tetrakis(4-chlorophenyl)borate) participates in the transduction process at the SC/ISM interface to stabilize the electrode potential and provide high reproducibility. It was further proved that the introduction of CoWSe2 as the SC layer maintains an excellent anti-interference to water layers, light, and gas. Hence, the CoWSe2-based ASS-NO3--ISEs achieve accurate detection for free NO3- in wetland soil and the estuary of the Yellow River delta.
Related Concept Videos
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Controlled-Current Coulometry: Overview
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodeposition
Electrodeposition can...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...