Comparison of Algorithms for Artifact Detection of Perioperative Blood Pressure Data: A Retrospective Analysis
Melanie Maria Kuhrn1,2, Mathias Maleczek1,2, Daniel Laxar1,2
1Department of Anesthesiology, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Austria.
Background:
Perioperative blood pressure data often contain artifacts that can compromise data integrity for clinical decisions and research.
Objectives:
The main objective of this retrospective analysis was to evaluate the efficiency and reliability of various algorithms for artifact detection in perioperative blood pressure data, specifically assessing their performance in different clinical scenarios and measurement methods.
Methods:
Data from 106 patients at the Medical University of Vienna were analysed using algorithms based on the interquartile range, Z-Score, Cut-off methods, and Moving Mean/Median. Validation involved comparisons against a reviewer standard set by anaesthesia experts.
Results:
Using a standard deviation based algorithm was most effective, offering superior accuracy and reliability across scenarios although sensitivity was below 60% for all used algorithms.
Conclusion:
Our results support a scenario-specific approach to artifact detection, underlining the need for research into adaptive algorithms that enhance data quality for clinical and research applications.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure