Related Experiment Video
Updated: May 10, 2025

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Tracheostomy Cuff Herniation following Cardiac and Pulmonary Arrest
Yasmin Chaibakhsh1, Mohammad Ziae Totonchi Ghorbani1, Nader Givtaj2
1Department of Cardiac Anesthesia, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Abstract:
Tracheostomy is a common procedure performed on patients who require long-term airway maintenance and ventilation support. It is preferred over endotracheal intubation due to its reduced airway resistance, lower risk of displacement compared with the endotracheal tube, increased patient comfort, improved weaning from mechanical ventilation, and enhanced suction capabilities. According to the literature, patients needing airway support for fewer than 12 days can undergo translaryngeal intubation, while tracheostomy is indicated for patients requiring ventilatory support for more than 20 days. Although tracheostomy is frequently performed in ICUs and operating rooms, several complications can arise following the procedure. These complications include leakage, obstruction of the tracheal tube, minor or major bleeding or oozing, barotrauma, infections, tracheoesophageal fistula, stenosis, and injury to surrounding peripheral tissues such as arteries, veins, and nerves.1 While herniation of the endotracheal cuff is a more common cause of airway obstruction and hypoxia, tracheostomy tube cuff herniation is a rare complication of this procedure.1-7 In this report, we present a rare case of cardiopulmonary arrest following the implantation of a tracheostomy tube cuff in a female patient and its management.
More Related Videos
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...

