Related Experiment Video
Updated: May 10, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Capacity configuration optimization of electricity heat hydrogen regional integrated energy system considering
Tianhe Sun1, Runqi Sun1, Xiaoyi Qian1
1Key Laboratory of Energy Saving and Controlling in Power System of Liaoning Province, Shenyang Institute of Engineering, Shenyang, P R China.
Abstract:
Rationally configuring the capacity of the electricity heat hydrogen regional integrated energy system is conducive to improving its economy and energy utilization efficiency. In view of the dual effects of the uncertainties of energy supply and demand in system configuration on power supply reliability and wind power consumption, a min-max-min two-stage robust optimization configuration model aiming at the minimum sum of system investment and operating cost is established for achieving an optimal capacity configuration of multi-vector technologies involved in it. On the basis of typical scenarios, a box-type uncertainty set independent of a probability distribution is used to describe the uncertainty of wind power and demand and the robustness constraint is formed. An innovative parameter, named the uncertainty adjustment parameter, is introduced into the box-type uncertainty set to avoid sacrificing economic benefits caused by too conservative configuration scheme. In this paper, the column and constraint generation algorithm and strong duality theory are used to decompose the original problem into the linearized master problem and subproblem, which can improve the solving speed. Finally, an integrated energy system in the north of China is taken as a case study. The results demonstrate that the proposed model effectively addresses the uncertainty problems of wind power and demand, leading to improved reliability and wind power integration performance. By changing the uncertainty adjustment parameter, the conservativeness of the configuration scheme can be flexibly adjusted. The effectiveness and applicability of the proposed model and solution algorithm are verified.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Related Concept Videos
Load-frequency control
Maximum Power Flow and Line Loadability
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Power System Distribution
The transmission system is designed...
Control of Power Flow
Turbine-Governor Control