Correction of stomach cancer CT attenuation values for variations due to differences in CT imaging conditions through
Jeong Min Seo1, Sun Young Baek1,2, Woo Kyoung Jeong1
1Department of Radiology, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea.
Purpose:
To develop methods for correcting variations in CT attenuation values of advanced gastric cancer (AGC) due to differences in CT imaging conditions using repeated pre-treatment CT scans.
Methods:
A total 211 patients (146 men) with AGC who underwent pre-treatment CT twice were included in this retrospective study. The Pearson correlation between the difference in tumor attenuation values measured on both CT scans and the difference in attenuation values of other organs was analyzed. A formula to correct tumor CT attenuation values was developed using univariate linear regression analysis.
Results:
The Pearson correlation coefficient was the highest between the difference in tumor attenuation values and that of the main portal vein (MPV) attenuation values (0.86, P <.01). The formula to correct tumor attenuation values was as follows: calculated tumor attenuation value on CT scan 2 = tumor attenuation value on CT scan 1 - (-3.5 + 0.4 x (MPV attenuation value on CT scan 1 - MPV attenuation value on CT scan 2)). The mean difference between calculated and actual tumor attenuation values was 1.6 HU (SD, 8.7; range -22.5-24.72), with a Pearson correlation coefficient of 0.95 (P <.01).
Conclusion:
Utilizing the attenuation value of the MPV allows for correction of variations in tumor attenuation values caused by different CT imaging conditions, enabling the prediction of reproducible tumor attenuation in patients with AGC. Future studies are needed to validate these findings and address the study's limitations, including its retrospective design and the absence of unenhanced CT data.
Advances In Knowledge:
The attenuation value of the MPV can be used to predict reproducible tumor attenuation values in gastric cancer.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET