Related Experiment Video
Updated: May 12, 2025

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
Published on: November 21, 2019
Estimating the hysteresis loss in magnetic nanoparticles by magnetic particle spectroscopy
Samuel Goegebeur1, Katrijn Everaert1,2,3, Patricia Radon2
1Department of Solid State Sciences, Ghent University, Belgium, Krijgslaan 281/S1, 9000 Gent, Belgium.
Abstract:
Objective.Magnetic fluid hyperthermia is a promising adjuvant cancer therapy presently approaching clinical application. The therapeutic effect stems from the heat produced by magnetic nanoparticles (MNPs) administered to the tumor site and exposed to an AC magnetic field applied from outside the body. The objective of our study is to improve the integration of magnetic particle imaging (MPI) and hyperthermia as a theranostic application by allowing a real-time monitoring of local heat generation.Approach.The area of the dynamic hysteresis loop of the MNP is a measure of the heat produced by the MNP. However, depending on the specifics of the measurements, an accurate determination of the dynamic hysteresis loop of MNPs by conventional magnetic particle spectroscopy (MPS) can be hindered due to missing information of the first harmonic. The method presented in this work provides a solution to this problem by extracting the area of the hysteresis loop from measured MPS spectra through the reconstruction of the first harmonic.Main results.The method was tested on three distinct commercial MNP systems and found to be in good agreement with hysteresis loops directly obtained through AC magnetometry, confirming the method's reliability.Significance.This advancement enables accurate real-time monitoring of the energy dissipated as heat by the particles during MPS measurements and thus directly contributes to the development of MPI-guided hyperthermia.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Ferromagnetism
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Paramagnetism

