Related Experiment Video
Updated: May 10, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Wearable Devices for Quantifying Atrial Fibrillation Burden: A Systematic Review and Bayesian Meta-Analysis
Ioannis Anagnostopoulos1,2, Dimitrios Vrachatis1,3,4, Maria Kousta1
1Department of Interventional Cardiology and Electrophysiology, Evgenidio Hospital, 11528 Athens, Greece.
Background:
Atrial fibrillation (AF) is the most common supraventricular arrhythmia and is associated with an impaired prognosis. Studies using implantable cardiac monitors suggest that this association is closely linked to AF burden, defined as the percentage of time spent in AF. Consequently, there is a growing need for affordable and comfortable alternative devices, such as wearables, capable of reliably monitoring AF burden in patients with AF.
Methods:
Major electronic databases were searched for studies comparing AF burden quantification using wearables and reference ECG monitoring methods. A Bayesian approach was adopted for the final analysis.
Results:
Six studies, including a total of 448 patients and 36,978 h of valid simultaneous recordings, were analyzed. Bayesian analysis revealed no statistically significant differences between wearables and reference methods in AF burden quantification. The mean error was 1% (95% CrIs: -4% to 7%). Similar findings were observed in the subgroup analysis of studies assessing only smartwatches. Between-study heterogeneity was low, and no evidence of publication bias was detected.
Conclusion:
Our analysis suggests that AF burden quantification using wearables is comparable to reference ECG monitoring methods. These findings support the potential role of wearables in clinical practice, particularly for research and prognostic purposes. However, more studies are needed to determine whether the observed statistical equivalence translates to clinical significance, thereby supporting the widespread use of wearables in the assessment of rhythm control therapeutic strategies.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: