Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart
Felix Ausbuettel1, Sabah Khwamurad2, Murad Haj Abdo2
1Department of Cardiology, University Hospital Marburg, Baldingerstraße, 35043 Marburg, Germany.
Abstract:
(1) Background: The measurement of hemodynamic parameters has proven to be crucial in the treatment of hospitalized heart failure patients, necessitating invasive measurement by right heart catheterization (RHC). The reliability of whole-body impedance cardiography (ICG) among this cohort has not been investigated to date; (2) Methods: The RHC and whole-body ICG examinations measured cardiac output (CO), the cardiac index (CI), total peripheral resistance (TPR), and pulmonary vascular resistance (PVR). To assess the accuracy of the whole-body ICG measurement, bias and precision were calculated as the mean difference and the twofold standard deviation between the average values of measurements; (3) Results: A total of 203 patients were analyzed. No significant bias was observed between the non-invasive CO and CI measurements when compared with the RHC measurements (-0.14 ± 2.56 L/min, p = 0.1; -0.09 ± 1.3 L/min/m2, p = 0.06), but a significant bias occurred in the measurement of non-invasive TPR and non-invasive PVR (-1243 ± 3510 dyn × s-1 × cm-5, p = 0.001; -121 ± 504 dyn × s-1 × cm-5, p < 0.001); (4) Conclusions: CO and CI can be measured with whole-body ICG among hospitalized CHF patients with acceptable accuracy. The reliability of measuring TPR and PVR should be further investigated.
More Related Videos
08:25Impedance Pneumography for Minimally Invasive Measurement of Heart Rate in Late Stage Invertebrates
Published on: April 4, 2020
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...