Mechanisms of Cardiac Implantable Electronic Device Interference With the Tricuspid Valve Apparatus
Karima Addetia1, Michael Henry1, Heather Smith1
1Department of Medicine, Section of Cardiology, University of Chicago Heart and Vascular Center, Chicago, Illinois.
Abstract:
Cardiac implantable electronic devices (CIEDs) have been implicated in the development of tricuspid valve (TV) dysfunction. However, the mechanisms of dysfunction are not well characterized. We sought to define the prevalence, location and mechanisms of CIED-TV interference based on direct inspection of gross pathologic specimens from consecutive patients with CIEDs who had undergone orthotopic heart transplantation (OHT). CIED-interference was classified by location (septal, posterior or anterior trigone of the RV), portion of TV apparatus involved (leaflet(s) only, sub-tricuspid apparatus (STA) only or a combination of both leaflet and STA) and type of interference (adherence, trapping or both). Sixty-two cases of CIED-TV interference were identified (5 leaflet, 30 STA and 27 leaflet and STA). The majority of patients had nonischemic cardiomyopathy (81%) and leads in situ for <10 years (77%). Most CIED-TV interference involved either the posterior (n = 23, 37%), septal (n = 15, 24%) or posteroseptal regions of the RV (n = 16, 26%). Interference with the anterior leaflet or anterior STA was rare. STA interference consisted of lead trapping behind the papillary muscles or chordae alone (n = 6), lead adherence with trapping (n = 21) and lead adherence alone (n = 3). Combination STA and leaflet interference consisted of adherence and trapping (n = 20) and adherence without trapping (n = 7). In conclusion, CIED-TV interference occurs most frequently with the STA in the posterior and septal regions of the RV. These findings have the potential to instruct imagers on how to evaluate for CIED-TV interference in an era where, elucidating the mechanism of TV dysfunction and considering options for repair is gaining momentum.
More Related Videos
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...