Lead-Free Potassium Sodium Niobate-Based Wearable Ultrasonic Patches for Blood Pressure Detection
Yajun Sun1, Yi Quan1, Jie Xing2
1Faculty of Intergrated Circuit, Xidian University, Xi'an 710071, China.
Abstract:
Ultrasound is one of the most promising methods for blood pressure monitoring due to its harmless, non-invasive, and high-precision characteristics. To further enhance the biocompatibility of ultrasound blood pressure monitors, this work reports wearable ultrasonic patches for blood pressure monitoring based on lead-free KNN (potassium sodium niobate)-based materials. The patches are designed and fabricated with a center frequency of 5 MHz and dimensions of 2.8 mm × 2.8 mm, optimized for both electrical impedance matching and vascular detection. Moreover, biocompatible silicone rubber is used for the packaging. The wearable ultrasonic patches are demonstrated to effectively transmit and receive signals. The diameter of artificial blood vessels is measured to validate the vascular diameter detection capability of the patches. The relationship between blood pressure and vascular diameter is then calculated. A radial artery vascular system platform is built to simulate changes in human blood pressure. Finally, the patches are shown to successfully measure the variation in vessel diameters on this platform. These patches exhibit sufficient detection ability, good biocompatibility, and can adhere tightly to human skin without coupling agents, providing the possibility for safe, sustainable, comfortable, and wearable long-term blood pressure monitoring.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: