Related Experiment Video
Updated: May 10, 2025

06:29
Effect of Artificial Tear Formulations on the Metabolic Activity of Human Corneal Epithelial Cells after Exposure to Desiccation
Published on: May 2, 2020
3.8K
Characterization of Individuals with High-Frequency Artificial Tear Supplement Use
Wan-Lin Wu1, Shu-Wen Chang1,2
1Department of Ophthalmology, Far Eastern Memorial Hospital, No. 21, Section 2, Nanya S. Road, Banqiao District, New Taipei City 220, Taiwan.
Journal of Clinical Medicine
|April 26, 2025
Summary
High-frequency artificial tear users experience worse dry eye symptoms and require more cyclosporine treatment. Reducing drop usage improved symptom scores, indicating potential benefits for frequent users.
Area of Science:
- Ophthalmology
- Dry Eye Disease Research
- Ocular Surface Disease
Background:
- High-frequency topical eye drop usage is common in dry eye disease management.
- Understanding predisposing factors for frequent use is crucial for effective treatment strategies.
Purpose of the Study:
- To identify dry eye parameters associated with high-frequency artificial tear usage.
- To estimate the prevalence of high-frequency eye drop use in a dry eye patient cohort.
- To evaluate the impact of reduced drop usage and the need for advanced treatments like cyclosporine.
Main Methods:
- A cohort of 5594 dry eye patients was analyzed, categorizing users as high (≥1 drop/hour) or low (<4 drops/day).
- Evaluated differences in dry eye symptoms (OSDI, SPEED), tear parameters (SPK, FTBUT, LLT, MGE), and blink patterns.
- Assessed follow-up compliance and treatment outcomes, including cyclosporine initiation.
Main Results:
- High users exhibited significantly worse symptom scores, increased blinking, lower Schirmer scores, higher SPK, and shorter FTBUT.
- No differences were observed in lipid layer thickness or meibomian gland expressibility.
- High users showed greater follow-up compliance and a significantly higher likelihood of receiving cyclosporine treatment (15.4% vs 1.1%).
Conclusions:
- Elevated OSDI (>40), SPEED (>12), and low Schirmer scores (≤3 mm) predict high-frequency eye drop use.
- High-frequency use, seen in 3.2% of patients, may involve environmental trigger hypersensitivity.
- Frequent users demonstrate a significantly greater need for advanced therapies such as cyclosporine.
Related Concept Videos
Accessory Structures of the Eye
1.3K
Optical perception, or vision, is an extraordinary sense dependent on converting light signals received via the ocular organs. These organs, known as eyes, are securely positioned within the bony cavities of the skull, called orbits. The orbits serve a dual purpose: a protective shield for the ocular globes and a stable attachment point for the soft ocular tissues. The eye's external protective mechanisms include the eyelids, which are edged with lashes that act as a barrier against foreign...
1.3K
Direct-Acting Cholinergic Agonists: Therapeutic Uses
615
Direct-acting cholinergic agonists have many therapeutic uses in various medical fields. Choline esters, including acetylcholine, have limited clinical utility due to their non-selectivity and short duration of action. Still, acetylcholine and carbachol are applied topically during ophthalmologic surgery to induce miosis. Pilocarpine, a muscarinic and ganglionic stimulator, effectively treats open-angle glaucoma and alleviates xerostomia and dry mouth caused by radiotherapy or Sjögren...
615

