Related Experiment Video
Updated: May 10, 2025

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder
Published on: June 7, 2024
Optimizing infusion-suction diameter ratio (ISDR) in ureteroscopy: in vitro pressure and flow prediction and
Fengqi Wang1,2, Yanqi Xie3, Baiyang Song1,4
1Department of Urology, The First Affiliated Hospital of Ningbo University, 59#, Liuting Street, Haishu District, Ningbo, 315000, Zhejiang, China.
Abstract:
To optimize channel configurations for a flexible ureteroscope incorporating both irrigation and suction channels, in vitro experiments were conducted with the aim of achieving safer and more efficient surgical procedures. Upper urinary tract models with integrated pressure-sensing ports were constructed based on CT urography reconstructions. Functional ureteroscope prototypes with various combinations of infusion and suction channel diameters were developed. Using a controlled constant-pressure irrigation system, intrarenal pressure measurements were obtained from the upper, middle, and lower calyces, as well as the renal pelvis. The effects of varying infusion pressures on irrigation flow rates and intrarenal pressure distribution were assessed. Regression models were subsequently established for renal pelvic pressure (RPP) and irrigation flow rate, allowing for the determination of the optimal channel diameter configuration by integrating model predictions with clinical requirements. At an infusion pressure of 500 cmH2O without active suction, the maximum Infusion-to-Suction Diameter Ratio (ISDR) that maintained RPP below the safety threshold was approximately 0.525, corresponding to an Infusion-to-Suction cross-sectional Area Ratio (ISAR) of about 0.276. Theoretically, the optimal combination of infusion and suction channel diameters that satisfies both pressure and flow criteria is 1.03 mm and 1.93 mm, respectively. These findings demonstrate that the ISDR, infusion channel caliber, and irrigation pressure are critical determinants of RPP and flow rate during ureteroscopic procedures. For ureteroscopes with integrated infusion and suction channels, maintaining an ISDR below 0.525-or an ISAR below 0.276-provides favorable balance between procedural safety and irrigation efficiency.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required