Related Experiment Video
Updated: Jul 14, 2026

Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Published on: October 12, 2015
The biosensor using the target urine volatile organic compounds for detecting diabetic kidney disease
Chatchai Kreepala1,2, Vichayut Suthat Na Ayutaya3, Rungrueang Phatthanakun4
1School of Internal Medicine, Institute of Medicine, Suranaree University of Technology, Nakhon Ratchasima, Thailand. Chatchaikree@gmail.com.
Abstract:
Volatile organic compounds (VOCs) are metabolic byproducts reflecting pathophysiologic processes and have been widely utilized as non-invasive biomarkers for disease differentiation. While VOCs have been extensively studied in oncology, their potential for diagnosing other prevalent public health conditions remains underexplored. This study serves as a proof-of-concept investigation, applying VOC-based detection to diabetic kidney disease (DKD), a leading cause of chronic kidney disease, to distinguish it from other nephrotic syndromes (NS). Utilizing metal oxide semiconductors, we analyzed urinary VOC profiles in 135 participants with biopsy-confirmed diagnoses. All gas sensors in the sensor chamber were of the n-type. Our results demonstrated that hydrogen and ethanol VOCs, measured at a minimum electrical resistance threshold of 4500 mV, effectively distinguished DKD from NS and other control groups. The mean differences in electrical resistance among DKD versus normal, DM without DKD, and NS were 868.3, 145.5, and 881.2 ohms, respectively (p < 0.05). Receiver operating characteristic (ROC) analysis yielded AUC values of 1.0, 0.64, and 0.99, respectively (p < 0.05), underscoring the method's diagnostic potential. VOCs primarily composed of hydrogen and ethanol in DKD patients exhibited distinct electron-release properties when interacting with metal oxide semiconductors compared to healthy individuals and NS patients. These findings suggest that urine-based VOC analysis has potential as a non-invasive alternative for distinguishing DKD from other glomerular diseases. This study highlights the feasibility of extending VOC-based biosensor technology beyond oncology, offering a novel diagnostic framework for broader clinical applications in public health and metabolic disease monitoring.
Related Concept Videos
Urine Studies I: Urinalysis
Microbial Biosensors
Diabetic Ketoacidosis l: Introduction
Diabetic Ketoacidosis ll: Pathophysiology
Diabetic Retinopathy
Diabetic Nephropathy

