Related Experiment Video
Updated: May 12, 2025

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Multistage characterization of label-derived oleamide: chromatographic purification with NMR structural elucidation
Chunwang Fu1, Fan Jiang1, Chunhua Li2
1Shenyang Xingqi Pharmaceutical Co., Ltd, Shenyang 110163, China. a18240424565@163.com.
Abstract:
Pharmaceutical labeling is widely used for drug information identification, though compatibility risks persist despite no direct drug contact. This migration risk arises from the semi-permeable nature of primary packaging materials, allowing label additives to permeate into drug formulations. A substantial number of emerging additives, either novel therapeutic agents or structural mimics of prohibited substances, hinder unambiguous liquid chromatography mass spectrometry (LC-MS) identification. To address this, a novel approach is suggested, involving chromatographic separation paired with nuclear magnetic resonance (NMR) spectroscopy for unknown compound identification. High performance liquid chromatography (HPLC) was used to screen the suspected chromatographic peaks and purify them, and then the purified fractions were structurally characterized by ultra-performance liquid chromatography-quadrupole time-of-flight mass (UPLC/Q-TOF-MS) and NMR. Finally, the extractable was identified as oleamide. To quantify oleamide in pharmaceutical labels, a mass spectrometry method with high sensitivity and high resolution was developed and validated using UPLC/Q-TOF-MS. The quantitative approach showed excellent linearity between roughly 0.15 and 2.05 μg mL-1, with limit of detection (LOD) and limit of quantification (LOQ) values of 50.72 and 153.83 ng mL-1 (R2 = 0.9994). The repeatability, precision, accuracy and robustness were verified to be acceptable. The safety assessment determined that the maximum daily exposure to oleamide in the label of the eye drops tested is 0.015 μg, which is well below the permitted daily exposure (PDE) limit of oleamide. These data demonstrate negligible toxicological risks and confirm the good compatibility between the labels and the ophthalmic formulation.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
11:27A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
Related Concept Videos
Olefin Metathesis Polymerization: Acyclic Diene Metathesis (ADMET)
Similar to cross-metathesis, ADMET also involves the formation of metallacyclobutane intermediate by [2+2] cycloaddition of one of the double bonds of a terminal diene with...
Olefin Metathesis Polymerization: Overview
Ruthenium-based Grubbs catalyst is the most commonly used catalyst for olefin metathesis polymerization. Grubbs catalyst consists...
Alkylation of β-Diester Enolates: Malonic Ester Synthesis
Olefin Metathesis Polymerization: Ring-Opening Metathesis Polymerization (ROMP)
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry
Factors Influencing Drug Absorption: Pharmaceutical Parameters