Related Experiment Video
Updated: Aug 19, 2026

Quantitative Autonomic Testing
Published on: July 19, 2011
"I can tell when my blood pressure is up, can't I?"
Abstract:
Forty-four insurance company employees were measured on blood pressure, moods, symptoms, and predictions of their blood pressures, twice daily for 10 days. Twenty subjects had elevated blood pressure and 24 did not. The measures were correlated within-subjects to determine if blood pressure predictions were associated with moods, symptoms, or blood pressure readings, and if moods and symptoms were related to blood pressure. Predictions of pressure were expected to be correlated with symptoms and moods, but not with blood pressure. No strong relationship was expected when blood pressure was compared to symptoms or to moods. The data showed that self-predictions of blood pressure were most strongly associated with reported symptoms, next with reported moods, and least with actual blood pressure. A comparison of subjects who were accurate in predicting their blood pressure with those who were not showed no differences in blood pressure levels, systolic blood pressure variation, self-esteem, or private body-consciousness. Subjects' beliefs that they could monitor blood pressure were little influenced by contrary information. The results suggest it would be an error to encourage subjects to believe they can successfully treat blood pressure elevations by monitoring symptoms related to blood pressure change.
Related Concept Videos
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Measurement of Blood Pressure

