Enhanced DWT for Denoising Heartbeat Signal in Non-Invasive Detection
Peibin Zhu1, Lei Feng1, Kaimin Yu2
1School of Ocean Information Engineering, Jimei University, Xiamen 361021, China.
None:
Achieving both accurate and real-time monitoring heartbeat signals by non-invasive sensing techniques is challenging due to various noise interferences. In this paper, we propose an enhanced discrete wavelet transform (DWT) method that incorporates objective denoising quality assessment metrics to determine accurate thresholds and adaptive threshold functions. Our approach begins by denoising ECG signals from various databases, introducing several types of typical noise, including additive white Gaussian (AWG) noise, baseline wandering noise, electrode motion noise, and muscle artifacts. The results show that for Gaussian white noise denoising, the enhanced DWT can achieve 1-5 dB SNR improvement compared to the traditional DWT method, while for real noise denoising, our proposed method improves the SNR tens or even hundreds of times that of the state-of-the-art denoising techniques. Furthermore, we validate the effectiveness of the enhanced DWT method by visualizing and comparing the denoising results of heartbeat signals monitored by fiber-optic micro-vibration sensors against those obtained using other denoising methods. The improved DWT enhances the quality of heartbeat signals from non-invasive sensors, thereby increasing the accuracy of cardiovascular disease diagnosis.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Discrete Fourier Transform
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: