Related Experiment Video
Updated: May 10, 2025

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
Vital Sign and Biochemical Data Collection Using Non-contact Photoplethysmography and the Comestai Mobile Health App:
Gianvincenzo Zuccotti1,2, Paolo Osvaldo Agnelli3, Lucia Labati2
1Department of Biomedical and Clinical Science, University of Milano, Milano, Italy.
Background:
Early detection of vital sign changes is key to recognizing patient deterioration promptly, enabling timely interventions and potentially preventing adverse outcomes.
Objective:
In this study, vital parameters (heart rate, respiratory rate, oxygen saturation, and blood pressure) will be measured using the Comestai app to confirm the accuracy of photoplethysmography methods compared to standard clinical practice devices, analyzing a large and diverse population. In addition, the app will facilitate big data collection to enhance the algorithm's performance in measuring hemoglobin, glycated hemoglobin, and total cholesterol.
Methods:
A total of 3000 participants will be consecutively enrolled to achieve the objectives of this study. In all patients, personal data, medical condition, and treatment overview will be recorded. The "by face" method for remote photoplethysmography vital sign data collection involves recording participants' faces using the front camera of a mobile device (iOS or Android) for approximately 1.5 minutes. Simultaneously, vital signs will be continuously collected for about 1.5 minutes using the reference devices alongside data collected via the Comestai app; biochemical results will also be recorded. The accuracy of the app measurements compared to the reference devices and standard tests will be assessed for all parameters. CIs will be calculated using the bootstrap method. The proposed approach's effectiveness will be evaluated using various quality criteria, including the mean error, SD, mean absolute error, root mean square error, and mean absolute percentage error. The correlation between measurements obtained using the app and reference devices and standard tests will be evaluated using the Pearson correlation coefficient. Agreement between pairs of measurements (app vs reference devices and standard tests) will be represented using Bland-Altman plots. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and likelihood ratios will be calculated to determine the ability of the new app to accurately measure vital signs.
Results:
Data collection began in June 2024. As of March 25, 2025, we have recruited 1200 participants. The outcomes of the study are expected at the end of 2025. The analysis plan involves verifying and validating the parameters collected from mobile devices via the app, reference devices, and prescheduled blood tests, along with patient demographic data.
Conclusions:
Our study will enhance and support the accuracy of data on vital sign detection through PPG, also introducing measurements of biochemical risk indicators. The evaluation of a large population will allow for continuous improvement in the performance and accuracy of artificial intelligence algorithms, reducing errors. Expanding research on mobile health solutions like Comestai can support preventive care by validating their effectiveness as screening tools and guiding future health care technology developments.
Trial Registration:
ClinicalTrials.gov NCT06427564; https://clinicaltrials.gov/study/NCT06427564.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:24A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure in the Leg
Preparation: