Optimal Effect-Site Concentration of Propofol for Hemodynamic Stability During Intubation with Dexmedetomidine: A
Huayuan Gao1, Junmei Wu1, Youwen Chen1
1Department of Anesthesiology, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian, People's Republic of China.
Background:
This study aimed to determine the 95% effective concentration (EC95) of propofol via target-controlled infusion (TCI) for endotracheal intubation at three different doses of dexmedetomidine.
Methods:
One hundred and eighty patients aged 18-60 and classified as American Society of Anesthesiologists (ASA) class I-II were enrolled to undergo general anesthesia. Patients were randomly assigned to one of the three groups (A, B, or C), receiving three different doses of dexmedetomidine (0.6, 0.8, or 1 μg/kg) infused over 10 min. Anesthesia was then induced with propofol TCI, followed by rocuronium. The biased coin design method was used to calculate the EC95 of propofol for successful intubation. The primary outcome endpoint was the EC95 of propofol for successful endotracheal intubation at each dexmedetomidine dose.
Results:
Sixty patients in each group completed the trial. The time from propofol administration to intubation in group C (132.5 ± 10.7 s) was significantly shorter compared to group A (140.2 ± 14.4 s, P<0.0001) and group B (142.6 ± 13.2 s, P=0.0037). Both the EC95 and the average total dose of propofol in group B [14.6 (10.8, 14.8) μg/mL and 3.6 ± 1.1 mg/kg] and C [12.7 (11.5, 12.8) μg/mL and 2.8 ± 1.0 mg/kg] were lower than those in group A [14.9 (4.5, 15.0) μg/mL and 3.8 ± 0.9 mg/kg] (P<0.001). The incidence of hypotension and bradycardia during induction was low in each group.
Conclusion:
The EC95 of propofol for endotracheal intubation across three different background doses of dexmedetomidine was determined. We suggest administering 1.0 μg/kg dexmedetomidine and then the EC95 of propofol for successful endotracheal intubation was 12.7 μg/mL.
Registration:
Chinese Clinical Trial Registry; Registration number: ChiCTR2400089952, URL:https://www.chictr.org.cn/showproj.html?proj=221236.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
10:32A Guide to In vivo Single-unit Recording from Optogenetically Identified Cortical Inhibitory Interneurons
Published on: November 7, 2014
Related Concept Videos
Parenteral Anesthetics: Overview
Depolarizing Blockers: Pharmocokinetics
Skeletal Muscle Relaxants: Adverse Effects
Unlike...
Depolarizing Blockers: Mechanism of Action
Succinylcholine is the most commonly used depolarizing blocker. Chemically, it constitutes two molecules of acetylcholine joined together by an acetate methyl group. They act on the receptors in the same way as acetylcholine. Because...
Inhalational Anesthetics: Overview
Factors Affecting Drug Distribution: Organ Perfusion Rate
Perfusion rate-limited distribution relies on the...