Related Experiment Video
Updated: May 9, 2025

A Mouse Model of Orthopedic Surgery to Study Postoperative Cognitive Dysfunction and Tissue Regeneration
Published on: February 27, 2018
Correlation of intraoperative blood pressure variability and postoperative delirium in elderly hip fracture surgery
Peng Yang1, Yu Fan2, Wanyun Tang3
1Department of Anesthesiology, Zigong First People's Hospital, 643000, Zigong, People's Republic of China.
Abstract:
This study investigates the relationship between intraoperative blood pressure variability (BPV) and postoperative delirium (POD) after hip fracture surgery in geriatric patients. A retrospective analysis was conducted on 1002 geriatric patients who underwent hip fracture surgery. Intraoperative BPV was mainly quantified using the coefficient of variation in mean arterial pressure (CV-MAP). Patients were stratified into two groups (CV-MAP ≤ 10% vs. > 10%). Propensity score matching (PSM) balanced baseline characteristics. Multivariable logistic regression evaluated the association between CV-MAP and POD. Restricted cubic spline (RCS) analysis examined dose-response relationships. Subgroup analyses and interaction tests were conducted to examine effect modifications. POD occurred in 198 patients (19.8%). Patients with CV-MAP > 10% showed a significantly higher occurrence of POD than those with CV-MAP ≤ 10%, both before (24.6% vs. 16.4%, p < 0.001) and after PSM (25.2% vs. 18.9%, p = 0.032). Adjusted logistic regression confirmed CV-MAP > 10% as an independent predictor of POD (adjusted OR: 1.45, 95% CI 1.03-2.03, p = 0.033). RCS analysis revealed a nonlinear positive association between CV-MAP and POD risk. Subgroup analyses identified significant interactions between CV-MAP and variables such as age and ASA classification (p < 0.05). Elevated intraoperative BPV is independently associated with an increased risk of POD in elderly hip fracture patients, with nonlinear effects and potential modifiers. These findings underscore the importance of individualized blood pressure management to mitigate POD risk.
More Related Videos
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...

