Related Experiment Video
Updated: May 15, 2025

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Effect of pH on stability and solid phase extraction of urinary free metadrenaline measurement by liquid
Lindsay McDonald1, Craig Livie1, Karen Smith1
1Department of Clinical Biochemistry, Glasgow Royal Infirmary, Glasgow, UK.
Abstract:
BackgroundMeasurement of urine free metadrenalines offers potential diagnostic and practical advantages over urinary fractionated metadrenalines in detection of phaeochromocytoma and paraganglioma, including sample collection without acid preservative. Here, we evaluate stability with and without sample acidification as well as pH implications for analysis by solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry.MethodsSpot urine samples were adjusted to pH 3 or unacidified on day of collection and stored at room temperature, 4°C or -20°C, for up to 28 days to assess changes in free metadrenaline concentrations over time. Extraction of unacidified versus acidified urine was examined by comparing peak areas and measuring concentrations present in sample eluents according to two SPE methodologies.ResultsFree metadrenalines remained stable in urine with or without acidification for up to 28 days, with mean reduction in concentrations of <10% for all storage conditions. Measured concentrations progressively increased without acidification at room temperature at low concentrations but remained constant when spiked with pathological concentrations. Peak areas were up to 97-fold lower in acidified than unacidified samples when extracted using weak cation exchange (WCX). On average 64% of analyte eluted in the flowthrough in acidified samples relative to 1.5% without acidification. By contrast, over 99% was retained in the extract using polar extraction at either pH.ConclusionUrine free metadrenalines remain stable at room temperature for up to 28 days and are more efficiently extracted without use of acid preservative if using WCX methodology.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Extraction: Advanced Methods