A novel Z-shaped anti-rotation rod for atlantoaxial dislocation reduction: finite element analysis
Mandi Cai1,2, Rencai Ma2, Junlin Chen2
1The First School of Clinical Medicine, Southern Medical University, No.1838 North of Guangzhou Road, Guangzhou, 510515, People's Republic of China.
Background:
C1-C2 pedicle screw-rod fixation (PSR) is widely used for atlantoaxial dislocations. However, its limited reduction capacity in refractory cases necessitates additional release surgeries, increasing operative risks including prolonged surgical time and expanded tissue damage. We developed a novel Z-shaped anti-rotation rod to improve reduction capability, but its biomechanical performance requires evaluation.
Methods:
A nonlinear atlantoaxial instability three-dimensional (3D) C0-C3 finite element model was constructed using computed tomography images from a 25-year-old healthy male without a history of cervical spine diseases. Based on this model, two C1-C2 fixation configurations were simulated: conventional pedicle screw-rod (PS-CR) and pedicle screw-Z-shaped rod (PS-ZR). Reduction forces were measured and compared. Range of motion (ROM), stress distribution and peak stress values of the implants were recorded and compared under six loading conditions including flexion, extension, lateral bending, and axial rotation.
Results:
Both configurations achieved a greater than 98% reduction in the C1-C2 segmental ROM, with similar compensatory motions in adjacent segments. The reduction force of PS-ZR showed significant advantages (2-8 mm range), achieving a maximum reduction force of 88.544 N, which is 1.67 to 3.68 times that of PS-CR. The PS-ZR system experiences greater stress compared to the PS-CR system, escalating with Z-rod height. Regarding stress distribution and peak values of rods, the maximum stress on the PS-CR system was mainly concentrated at the connection between the rod and the screw nut while the maximum stress on the PS-ZR system was concentrated at the transition part of the "Z" shape.
Conclusions:
Both PS-CR and PS-ZR configurations provide reliable and comparable stability. Compared to the PS-CR configuration, the PS-ZR configuration provides superior reduction force and stability, potentially reducing the need for additional release surgery and surgical time. This novel design has significant clinical implications for improving fixation techniques.
More Related Videos
Related Concept Videos
Statically Indeterminate Problem Solving
Temperature Dependent Deformation
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stability of structures
Transformation of Plane Strain
Under plane strain conditions, typical for members where one dimension significantly exceeds the others, deformations and resultant strains are...
Plastic Deformations of Members with a Single Plane of Symmetry