Purpose:
To evaluate the effect of ceramic firing cycles on the interface of screw-retained implant-supported metal-ceramic fixed dental prostheses (FDPs).
Materials And Methods:
A total of 22 frameworks were produced in cobalt-chrome (CoCr) alloy using an integrated CAD/CAM system. The frameworks were manufactured with an additive process on the milled implant-framework interface (IFI). The total distortion of the interface was measured before (T1) and after (T2) the ceramic firing thermal cycles. The interface distortion was measured using a coordinate measuring machine (CMM) with an uncertainty of 2.5 nm, a resolution of 25 nm, and a universal software for dimensional metrology. To test whether there was a significant difference in total 3D distortion, Kruskal-Wallis test and Dunn test were employed; linear distortions between groups were compared using Kolmogorov-Smirnov test and Mann-Whitney test. A P value of ≤ .05 was considered statistically significant.
Results:
The total 3D distortion between the nominal value and T1 was 0.5 ± 1.0 μm, between the nominal value and T2 was 10.5 ± 4.9 μm, and between T1 and T2 was 10.6 ± 4.9 μm. The distortion between T1 and the nominal value was significantly smaller than that between the other two groups. The average deviations around the three axes and diameters were not significantly different among the three groups.
Conclusions:
CAD/CAM manufacturing of the IFI is an accurate process and does not present appreciable distortions. The ceramic firing cycles induce 3D-interface distortion. The observed distortion values were well below clinically relevant levels.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or...
Veneer
Other veneering techniques include plain-slicing, quarter-slicing, and rift-slicing. These...