Related Experiment Video
Updated: May 9, 2025

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Impact of exterior envelope thermal performance on energy demand and optimization strategies for university
Zu-An Liu1, Yan Li1, Jiawen Hou2
1School of Civil Engineering, Xuzhou University of Technology, Xuzhou, 221018, China.
Abstract:
It is very different from that of ordinary buildings due to the unique operational characteristics of university teaching-office buildings, and the energy-saving potential is huge, among them, the building's exterior envelope is an important factor in its energy loss. It is an important basis for building energy conservation to explore the influence of the thermal parameter of the building exterior envelope on energy consumption from the perspective of thermal theory. Meanwhile, most of the buildings are old in university, limited by the actual conditions, studying the energy-saving optimization scheme from the main influencing factors and actual characteristics is a prerequisite for achieving high efficiency and energy saving. Therefore, based on the actual characteristics of university buildings, the influence law of the thermal performance of the exterior envelopes on energy demands is explored in this study through numerical simulation, and an energy-saving optimization scheme is proposed based on the existing materials. The results show that: (1) For university buildings in Chengdu, the energy-saving effect of the interior thermal insulation in exterior wall is the best; (2) the effect of insulation material type on total annual load tends to be the same as the insulation thickness is increased and stabilizes after the energy savings rate reaches 20%; (3) the selection of facing materials with low solar radiation absorption coefficients for exterior wall and roof has a much higher impact on cooling loads than on heating loads; (4) the suitable range of the heat transfer coefficient of the exterior window is 2.5 ~ 3.5, and the solar heat gain coefficient is 0.1 ~ 0.5; (5) using the optimization scheme can be saved by 18% of the heating load, 33% of the cooling load, and 28% of the total load compared to the status quo. The research results can provide a theoretical basis and data reference for energy-saving renovation of educational buildings.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Insulation Coordination
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Energy Conservation and Bernoulli's Equation
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...