Related Experiment Video
Updated: May 9, 2025

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Published on: November 7, 2017
Measurement of magnetic properties in boiler steel at high temperatures using a U-shaped yoke
Mingxing Cao1, Zhigao Zhang2, Jian He1
1Center for Advanced Metering Infrastructure, National Institute of Metrology, 18, Beisanhuandonglu, Chaoyang District, Beijing, 100029, China.
Abstract:
This paper presents a specially developed system for measuring the magnetic properties of boiler steel based on a U-shaped yoke. The novelty of this system lies in the unique combination of two main features: (1) a compensation method for accurately measuring iron loss and (2) the implementation of ultra-high-temperature measurement conditions. Firstly, a small measurement coil is used to measure the leakage magnetic flux. By subtracting the leakage magnetic flux from the measurement result, precise local magnetic flux compensation is accomplished. And an iron-loss algorithm is then employed to eliminate the influence of the U-shaped yoke. Secondly, a magnetic property measurement method capable of operating at temperatures up to 630 °C is proposed. The specific total loss (Ps) is 34.398 W/kg, and the amplitude permeability (Ua) reaches 102.04. The influence of the gap between the sample and the U-shaped yoke is preliminarily validated by a simulation model. This measurement system represents the first successful attempt to provide stable and physically accurate results, addressing the requirements for the in-situ detection of material degradation of boiler steel in special equipment.
More Related Videos
Related Concept Videos
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Ferromagnetism
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Field Of A Current Loop