Thermal Rejection Assessment: New Strategies for Early Detection.
Irina Filz von Reiterdank1,2,3,4, Rohil Jain1,2, Eloi de Clermont-Tonnerre1,2,4,5
1Department of Surgery, Center for Engineering for Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.
Thermal imaging detects early signs of graft rejection in vascularized composite allotransplantation (VCA) before clinical signs appear. This non-contact method aids in monitoring rejection, even in pigmented skin, potentially reducing invasive biopsies.
Area of Science:
- Transplantation immunology
- Medical imaging
- Regenerative medicine
Background:
- Diagnosing pathologies in pigmented skin is challenging for physicians.
- Clinical observation of rejection in vascularized composite allotransplantation (VCA) is difficult, especially in pigmented skin.
- Non-invasive monitoring could improve early detection of VCA rejection.
Purpose of the Study:
- To evaluate thermal assessment as a non-invasive method for early detection of VCA rejection.
- To assess the efficacy of thermal imaging in both pigmented and non-pigmented VCA models.
- To compare thermal assessment with clinical and histological assessments of rejection.
Main Methods:
- Rodent partial hindlimb VCA model with pigmented and non-pigmented allogeneic recipients.
- Daily thermal assessment using infrared (IR) gun and forward-looking IR (FLIR) imaging.
- Daily clinical assessment and histological biopsies on postoperative days 1, 3, and 7.
Main Results:
- Clinical and histological assessments showed rejection signs on postoperative day 3.
- Thermal assessment detected significant temperature differences as early as postoperative day 1.
- IR gun detected decreased temperature in rejecting grafts compared to controls.
Conclusions:
- Thermal assessment is a capable non-contact tool for early detection of VCA graft rejection.
- This method identifies rejection signs before clinical symptoms are apparent, irrespective of skin pigmentation.
- Thermal assessment can potentially reduce the need for invasive biopsies, improving patient outcomes.
Related Concept Videos
Mechanism of heat transfer
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Decreased Body Temperature
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...