Related Experiment Video
Updated: Apr 9, 2026

Diagnostic Ultrasound Imaging of Mouse Diaphragm Function
Published on: April 21, 2014
Diaphragm Thickness and Contraction During Non-Invasive Ventilation: An Ultrasound Study
Stefano Nobile1, Annamaria Sbordone1, Nicola Salce2
1Neonatal Unit, Fondazione Policlinico Universitario "A. Gemelli", 00168 Rome, Italy.
Objectives:
Non-invasive ventilation (NIV) is a widely used treatment for neonatal respiratory distress syndrome (RDS). Data on diaphragm contractility and thickness during NIV is scarce. We aimed to describe changes in diaphragm thickness/contractility during NIV and to explore associations with NIV discontinuation failure.
Methods:
This is a single-center prospective study. Diaphragmatic ultrasound was performed weekly during NIV, then within 7 days from NIV discontinuation. Diaphragm thickness was measured at end-inspiration (DTI) and end-expiration (DTE). Diaphragm thickening fraction (DTF) was calculated as (DTI-DTE/DTE). The clinical characteristics of patients and NIV discontinuation failure were recorded. Univariate analysis, logistic regression and linear regression were performed to describe diaphragm features during NIV and associations with NIV discontinuation failure.
Results:
We studied 17 NIV cycles (median duration 21 days). Median DTE increased from 0.12 cm (SD 0.05) at the start of NIV to 0.15 cm (SD 0.04) at NIV discontinuation. The mean DTF decreased from 32.8 (SD 16.8) at the start of NIV to 25.6 (SD 8.9) at NIV discontinuation. NIV discontinuation failure occurred in 23.5% of infants and was associated with higher DTI and DTE at the start of NIV and with a more pronounced decrease in DTI and DTE over the NIV cycle, compared to infants with NIV discontinuation success. There were no differences in neonatal outcomes between the infants with NIV discontinuation failure vs. success. We did not find any significant predictors of NIV failure.
Conclusions:
Diaphragm thickness increased, whereas DTF decreased over time on NIV in preterm infants with RDS. NIV duration was not associated with changes in diaphragm trophism. NIV discontinuation failure was associated with thicker diaphragm at the start of NIV, as well as with a reduction in diaphragm trophism over the NIV cycle.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...