Related Experiment Video
Updated: Jul 23, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Evaluation of Enhanced External Counter Pulsation (EECP) as an Alternative Treatment Modality for Hypertension: A
Ratnadeep Biswas1, HariOm Vaja2, Vishnu Shankar Ojha1
1From the Department of Medicine, All India Institute of Medical Sciences, Patna, Bihar India.
Abstract:
This systematic review and meta-analysis evaluate the efficacy of enhanced external counterpulsation (EECP) in reducing blood pressure among hypertensive patients. From an initial 323 articles, 37 studies involving 1504 patients met the inclusion criteria, with 11 included in the meta-analysis. EECP therapy durations ranged from 0.75 to 36.5 hours, with the majority around 35 hours. Meta-analysis revealed a significant reduction in systolic blood pressure (SBP) [mean difference (MD), -7.85 mm Hg; 95% CI, -9.59 to -6.11; P < 0.00001; I2 = 0%]. Diastolic blood pressure (DBP) also showed a significant decrease (MD, -3.94 mm Hg; 95% CI, -5.56 to -2.33; P < 0.00001; I2 = 45%). Mean arterial pressure did not significantly change (MD, -3.08 mm Hg; 95% CI, -7.51 to 1.34; P = 0.17; I2 = 77%). Funnel plots and statistical tests indicated no significant publication bias for SBP or DBP changes. EECP therapy significantly reduces both SBP and DBP in hypertensive patients, suggesting its potential as an effective adjunctive treatment for hypertension. However, the effect on mean arterial pressure remains inconclusive. The therapy's noninvasive nature, coupled with its demonstrated efficacy, supports broader clinical application. Further research with larger sample sizes and standardized protocols is necessary to better understand the mechanisms behind EECP and its long-term benefits in hypertension management.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Measurement of Blood Pressure
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme (ECE). Of...
Hypertension III: Clinical Manifestations and Diagnostic Studies