Twenty-Four Hour Ambulatory Blood Pressure Monitoring in Offspring Conceived Through Assisted Reproductive Technologies
Related Experiment Video
Updated: May 15, 2025

Author Spotlight: Exploring the Long-Term Health Impacts of Intracytoplasmic Sperm Injection on Offspring
Published on: May 17, 2024
Felix Sebastian Oberhoffer1, Pengzhu Li1, Magdalena Langer1
1Division of Pediatric Cardiology and Intensive Care, University Hospital, LMU Munich, 81377 Munich, Germany.
Background:
One in fifty infants is conceived through assisted reproductive technologies (ART). To date, data on the cardiovascular morbidity of ART individuals is ambiguous. This study investigated the vascular function of young ART subjects using 24 hour ambulatory blood pressure monitoring (24 h ABPM).
Methods:
ART subjects and spontaneously conceived controls matched in age as well as sex were enrolled. A 24 h blood pressure profile including pulse wave analysis was executed in all study participants. Blood pressure readings were assessed every 15 min during daytime and every 30 min during nighttime. The 24 h systolic/diastolic blood pressure (SBP/DBP) as well as central blood pressure, nocturnal blood pressure decrease, and 24 h pulse wave velocity (PWV) were analyzed.
Results:
A total of 41 ART individuals and 46 spontaneously conceived peers were included in the final analysis (mean age: 15.37 ± 5.46 years vs. 16.48 ± 5.23 years, p = 0.338). The 24 h SBP (112.74 ± 9.24 mmHg vs. 112.73 ± 6.70 mmHg, p = 0.997), 24 h DBP (65.61 ± 7.98 mmHg vs. 66.57 ± 7.03 mmHg, p = 0.550), 24 h central blood pressure, nocturnal blood pressure decrease, and 24 h PWV did not demonstrate significant differences between the ART and control group.
Conclusions:
In contrast to previous studies, no significant differences in 24 h blood pressure were demonstrated between ART subjects and spontaneously conceived peers. Hence, the results of this study do not indicate an unfavorable blood pressure profile in ART offspring. Larger multi-centric studies are needed to validate these results in the future.
More Related Videos
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
05:40Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: