Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Assessment of Spectral Computed Tomography Image Quality and Detection of Lesions in the Liver Based on Image
Areej Hamami1, Mohammad Aljamal1, Nora Almuqbil2
1Department of Medical Imaging, Faculty of Allied Medical Sciences, Arab American University, 13 Zababdeh, Jenin P.O. Box 240, Palestine.
Abstract:
Background: Spectral detector computed tomography (SDCT) has demonstrated superior diagnostic performance and image quality in liver disease assessment compared with traditional CT. Selecting the right reconstruction algorithm and tube voltage is essential to avoid increased noise and diagnostic errors. Objectives: This study evaluated improvements in image quality achieved using various virtual tube voltages and reconstruction algorithms for diagnosing common liver diseases with spectral CT. Methods: This retrospective study involved forty-seven patients who underwent spectral CT scans for liver conditions, including fatty liver, hemangiomas, and metastatic lesions. The assessment utilized signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), with images reconstructed using various algorithms (IMR, iDose) at different levels and virtual tube voltages. Three experienced radiologists analyzed the reconstructed images to identify the best reconstruction methods and tube voltage combinations for diagnosing these liver pathologies. Results: The signal-to-noise ratio (SNR) was highest for spectral CT images using the IMR3 algorithm in metastatic, hemangioma, and fatty liver cases. A strong positive correlation was found between IMR3 at 120 keV and 70 keV (p-value = 0.000). In contrast, iDOSE2 at 120 keV and 70 keV showed a low correlation of 0.291 (p-value = 0.045). Evaluators noted that IMR1 at 70 keV provided the best visibility for liver lesions (mean = 3.58), while IMR3 at 120 keV had the lowest image quality (mean = 2.65). Conclusions: Improvements in image quality were noted with SDCT, especially in SNR values for liver tissues at low radiation doses and a specific IMR level. The IMR1 algorithm reduced noise, enhancing the visibility of liver lesions for better diagnosis.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET