Optimal Wavelengths for Multispectral Short Wavelength Infrared Transillumination and Reflectance Imaging for Caries
1Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, 707 Parnassus Ave, San Francisco, CA 94143, USA.
Abstract:
Background/Objectives: The aim of this in vitro study was to determine the optimal combinations of wavelengths for short wavelength infrared (SWIR) multispectral transillumination and reflectance imaging of caries lesions on proximal and occlusal surfaces. Methods: The contrasts of (n = 76) caries lesions on the occlusal and proximal surfaces of extracted teeth were measured at 1050, 1300, and 1550 nm for occlusal transillumination and 1058, 1300, 1450, and 1675 nm for occlusal reflectance. All teeth were also imaged using radiography and microcomputed tomography (μCT) to verify lesion presence. A custom-fabricated handheld imaging probe suitable for clinical use and for the simultaneous acquisition of SWIR occlusal transillumination and reflectance (SWIR-OTR) images was used. Three high-power superluminescent diode lasers were used for transillumination, and a fiber-optic switch was used to switch between the transillumination wavelengths. Optical bandpass filters coupled with a tungsten halogen lamp were used for reflectance. All images were acquired at the same position and with the same field of view for comparison. Results: The highest contrasts in reflection were at 1450 and 1675 nm for occlusal and interproximal lesions, and the highest contrasts for transillumination were at 1050 and 1300 nm. Conclusions: This study suggests that the best wavelengths for SWIR-OTR are between 1000 and 1300 nm for transillumination and greater than 1400 nm for reflectance. Wavelengths beyond 1400 nm are advantageous for reflectance and yield significantly higher contrast. Wavelengths beyond 1300 nm are not promising for occlusal transillumination since internal water absorption leads to contrast inversion.
More Related Videos
11:05High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
07:06Simultaneous Evaluation of Cerebral Hemodynamics and Light Scattering Properties of the In Vivo Rat Brain Using Multispectral Diffuse Reflectance Imaging
Published on: May 7, 2017
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...