Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Adjusting a Traverse01:12

Adjusting a Traverse

29
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
29
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

589
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
589

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Choroid plexus remodeling linked to impaired CSF-mediated clearance and Alzheimer's disease progression.

Alzheimer's & dementia : the journal of the Alzheimer's Association·2026
Same author

Preoperative urge urinary incontinence and outcomes after thulium laser enucleation for benign prostatic hyperplasia.

World journal of urology·2026
Same author

Teleost intestinal microfold cells: identification, characterization, and mucosal antigen sampling in olive flounder (<i>Paralichthys olivaceus</i>).

Marine life science & technology·2026
Same author

Refractory Malignant Arrhythmia in a 4-Year-Old Child With Short QT Syndrome: Persistence for Hope.

JACC. Case reports·2026
Same author

Photorealistic 3D Holographic Display with Natural Defocus Effect.

Nature communications·2026
Same author

Phase contrast tomography (PCT).

Optics express·2026
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: May 9, 2025

In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
10:42

In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM

Published on: June 16, 2016

9.2K

Efficient misalignment correction for annular LED arrays in intensity diffraction tomography.

Ruizhi Zhu, Wenjie Zou, Runnan Zhang

    Optics Letters
    |May 1, 2025
    PubMed
    Summary
    This summary is machine-generated.

    A new method corrects misalignment in intensity diffraction tomography (IDT), improving 3D refractive index reconstruction accuracy. This label-free microscopy technique enhances resolution for biological imaging.

    More Related Videos

    Quantifying Intermembrane Distances with Serial Image Dilations
    07:45

    Quantifying Intermembrane Distances with Serial Image Dilations

    Published on: September 28, 2018

    6.3K
    Large-area Scanning Probe Nanolithography Facilitated by Automated Alignment and Its Application to Substrate Fabrication for Cell Culture Studies
    09:45

    Large-area Scanning Probe Nanolithography Facilitated by Automated Alignment and Its Application to Substrate Fabrication for Cell Culture Studies

    Published on: June 12, 2018

    9.6K

    Related Experiment Videos

    Last Updated: May 9, 2025

    In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
    10:42

    In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM

    Published on: June 16, 2016

    9.2K
    Quantifying Intermembrane Distances with Serial Image Dilations
    07:45

    Quantifying Intermembrane Distances with Serial Image Dilations

    Published on: September 28, 2018

    6.3K
    Large-area Scanning Probe Nanolithography Facilitated by Automated Alignment and Its Application to Substrate Fabrication for Cell Culture Studies
    09:45

    Large-area Scanning Probe Nanolithography Facilitated by Automated Alignment and Its Application to Substrate Fabrication for Cell Culture Studies

    Published on: June 12, 2018

    9.6K

    Area of Science:

    • Biophysics
    • Optical Microscopy
    • Computational Imaging

    Background:

    • Intensity Diffraction Tomography (IDT) is a label-free 3D microscopy method for refractive index (RI) reconstruction.
    • Accurate alignment is critical for IDT's high spatiotemporal resolution imaging performance.
    • Existing methods struggle with precise experimental setup and algorithmic model alignment.

    Purpose of the Study:

    • To develop an efficient misalignment correction method for annular LED arrays in IDT.
    • To enhance the resolution and accuracy of 3D RI reconstruction in IDT.
    • To provide a robust solution for label-free computational microscopy.

    Main Methods:

    • Introduced a misalignment correction method for IDT (mcIDT) using an improved Fourier-Mellin transform (FMT) algorithm.
    • Enhanced FMT for noise resistance in wavelength and positional corrections.
    • Employed a global positional misalignment model optimized via the least squares method for robust correction.

    Main Results:

    • mcIDT demonstrated significant improvements in resolution and accuracy for 3D RI reconstruction.
    • The method proved robust even with substantial experimental misalignments.
    • Experimental validation on resolution targets and biological samples (HepG2, C166 cells) confirmed superior performance.

    Conclusions:

    • mcIDT offers an efficient and flexible solution for label-free 3D volumetric imaging.
    • The integrated approach of algorithmic calibration and physical correction enhances IDT's practical utility.
    • This technique has broad applicability in biological and industrial computational microscopy.