Related Experiment Video
Updated: May 6, 2026

Single-cell Suction Recordings from Mouse Cone Photoreceptors
Published on: January 6, 2010
S cone increments and decrements: Nearly-linear perceptual scales and variable noise
1Department of Psychology, Northeastern University, Boston, MA 02115, USA.
None:
Two psychophysical experiments investigated perceptual differences between increases and decreases in stimulation of the short-wavelength (S) cone photoreceptors. In Experiment 1, observers' suprathreshold perceptual scale responses to S cone stimulation were estimated using the Maximum Likelihood Difference Scaling (MLDS) procedure. In Experiment 2, observers' pedestal discrimination thresholds were measured with a two alternative forced choice (2AFC) method. Both experiments were performed using incremental (S+) and decremental (S-) contrasts separately. Substantial asymmetry between S+ and S- was found in pedestal discrimination thresholds, but not in S+ and S- perceptual scales: perceived S cone contrast was nearly linear with S cone contrast for both polarities. To reconcile perceptual scales and thresholds, a model is proposed in which the noise in the S cone pathway is assumed to be proportional to the square root of stimulus contrast. The model works well for both the perceptual scales and forced-choice discrimination, indicating that S+ and S- signals are processed in an asymmetrical way, likely due to the physiological differences between S ON and S OFF pathways.
More Related Videos
10:05Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia
Published on: January 27, 2018
07:12Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Upsampling
Sensation
Absolute thresholds can quantify the sensitivity of sensory...
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...