Related Experiment Video
Updated: Jun 18, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Use of structural bone allograft in revision hip arthroplasty for massive acetabular defect: A systematic review and
Pietro Cimatti1,2, Nicolandrea Del Piccolo1, Alessandro Mazzotta1
1Reconstructive Orthopaedic Surgery Innovative Techniques - Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli Bologna Italy.
Purpose:
Managing substantial acetabular defects during revision total hip arthroplasty (rTHA) poses significant challenges, with a range of techniques available and ongoing discussions regarding their efficacy. This meta-analysis aimed to assess the failure rates associated with Paprosky type III and American Academy of Orthopaedic Surgeons (AAOS) types III-IV acetabular defects treated with structural allografts in conjunction with cemented cups, cementless cups, or reinforcement devices.
Methods:
A systematic review was performed utilising PubMed/MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews to identify pertinent studies published from January 1980 to 1 April 2024. The search employed terms related to acetabular impaction bone grafting, rTHA, and associated techniques. The main outcome measure was the implant failure rate over an 8-year period.
Results:
Twenty-eight studies met the established inclusion criteria, covering three therapeutic approaches: (1) structural allograft with a cemented cup (four studies), (2) structural allograft with a cementless cup (10 studies), and (3) structural allograft with reinforcement devices (21 studies). The overall 8-year implant failure rate was found to be 16% (95% CI, 11%-21%), with significant differences noted among the treatment modalities (p = 0.017). The failure rate was lowest for reinforcement devices (12%) and highest for cemented cups (30%). The predominant failure mechanism was aseptic loosening (68.9%), followed by infection (20.3%) and dislocation (10.8%). Rates of aseptic loosening were greater with cemented cups compared to cementless cups and reinforcement devices (19% vs. 13% and 6%, respectively; p = 0.023).
Conclusions:
Structural allografts combined with reinforcement devices yield favourable outcomes for managing large acetabular defects during revision THA, demonstrating significantly lower failure rates compared to other techniques. The addition of reinforcement devices substantially reduces the risk of implant failure.
Level Of Evidence:
Level III.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022