Related Experiment Video
Updated: May 9, 2025

08:20
Murine Distal Colostomy, A Novel Model of Diversion Colitis in C57BL/6 Mice
Published on: July 12, 2018
12.8K
On the Power of Diversion
1Department of Surgery, Thomas Jefferson University Sidney Kimmel Medical College, Philadelphia, Pennsylvania, USA.
Journal of Palliative Medicine
|May 5, 2025
Summary
No abstract available in PubMed .
Related Concept Videos
Deindividuation
26.0K
Deindividuation is a form of social influence on an individual’s behavior such that the individual engages in unusual or non-normal behavior while in a group setting. Why? Because in these group settings, the individual no longer sees themselves as an individual anymore, disinhibiting their behavior and personal restraint.
26.0K
Directional Relays
73
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
73
Significance of Displacement Current
4.2K
A displacement current is analogous to a real current in Ampère's law, participating in Ampère's law the same way as the usual conduction current. However, it is produced by a changing electric field. Displacement current is defined in terms of a time-varying electric field, and also has an associated displacement current density. By adding a term accounting for displacement current, Maxwell modified the existing Ampère's law, which is now called generalized...
4.2K
Reclosers and Fuses
71
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
71
Conservation of AC Power
314
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
314
Primary Distribution
81
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
81

