Related Experiment Video
Updated: May 9, 2025

Hepatic Progenitor Specification from Pluripotent Stem Cells using a Defined Differentiation System
Published on: May 10, 2020
A dual-cascade-activatable molecular probe with microenvironment-adapted performance for accurate differentiation of
Ying Wen1, Zefeng Hu1, Wenhao Tian1
1Key Laboratory of Chemical Biology and Molecular Engineering of Ministry of Education, Key Laboratory of Materials for Energy Conversion and Storage of Shanxi Province, Institute of Molecular Science, Shanxi University, Taiyuan, 030006, China.
Abstract:
Fluorescence imaging utilizing biomarker-activatable fluorescent probes has emerged as a powerful tool for the precise and early diagnosis of hepatopathy. However, the development of effective molecular probes remains challenging due to limitations, such as single-stimulus responsiveness and incompatible with microenvironment characteristic of hepatopathy. These limitations often result in a lower signal-to-noise ratio, false positives and ultimately reduced diagnostic accuracy. In this study, we developed a novel dual-lock-controlled fluorescent probe (Hdual) based on basic blue 3 dye. This probe was designed to be sequentially activated by two potential hepatopathy biomarkers, leucine aminopeptidase (LAP) and monoamine oxidase (MAO), through a cascade mechanism. Moreover, after addition LAP and MAO, Hdual exhibited a linear fluorescence change within a pH range of 6.2-6.8, ensuring high compatibility with the weakly acidic microenvironment characteristic of hepatopathy. The dual-cascade-activatable design, combined with the probe's microenvironment-adapted property, enabled Hdual to achieve a significantly higher target-to-noise ratio (T/N) of 2.40 in in vivo imaging for drug-induced liver injury, compared to "single-locked" probe (T/N < 0.79). Notably, Hdual demonstrated the ability to differentiate between cirrhotic and hepatitis B samples by analyzing patient blood samples through both fluorescent imaging and a distinct colorimetric change, observable either visually or via smartphone-based color analysis. These findings highlight Hdual's high specificity and accuracy in fluorescence imaging-based detection, underscoring its potential to improve the early diagnosis of hepatopathy.
More Related Videos
13:21Chemically-blocked Antibody Microarray for Multiplexed High-throughput Profiling of Specific Protein Glycosylation in Complex Samples
Published on: May 4, 2012
12:52IridiumIII Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015