Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.3K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Development and validation of HSP90AA1 as a risk gene in a HIF-1α pathway-related prognostic signature for hepatocellular carcinoma.

Biochemical and biophysical research communications·2026
Same author

Genomic Landscape and Clinical Impact of MTAP Loss in Driver-Positive NSCLC: Insights from a Large-Scale Real-World Chinese Cohort.

Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer·2026
Same author

Herbivore-induced stomatal closure in tomato is mediated by a Ca<sup>2</sup>⁺-dependent GLR-CPK27-SLAC1 pathway.

Molecular horticulture·2026
Same author

Biotransformation mechanisms of polycyclic aromatic hydrocarbons by Raphidocelis subcapitata: The role of cytochrome P450.

Ecotoxicology and environmental safety·2026
Same author

Pharmacological Targeting of NRF2 Represents a Promising Therapeutic Approach for Pyroptosis-Related Non-Alcoholic Fatty Liver Disease.

Current medicinal chemistry·2026
Same author

Evolution and Suppression of Spin Cycloid in Epitaxial BiFeO<sub>3</sub> Thin Films.

Advanced materials (Deerfield Beach, Fla.)·2026
Same journal

Efficient methods for wave propagation in electron microscopy.

Ultramicroscopy·2026
Same journal

Unsupervised deep image prior for sparse-view and limited-angle electron tomography.

Ultramicroscopy·2026
Same journal

Determination of the structure of the tertiary phase in the alloy Al<sub>10</sub>Mo<sub>10</sub>Nb<sub>10</sub>Ta<sub>10</sub>Ti<sub>30</sub>Zr<sub>30</sub> using convergent beam electron diffraction.

Ultramicroscopy·2026
Same journal

Predictive drift compensation of multi-frame STEM via live scan modification.

Ultramicroscopy·2026
Same journal

Deep PACBED: Multitask analysis of PACBED images using deep neural networks.

Ultramicroscopy·2026
Same journal

Guided progressive reconstructive imaging: A new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography.

Ultramicroscopy·2026
See all related articles

Related Experiment Video

Updated: May 9, 2025

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

4.7K

Robust projection parameter calibration in cryo-ET with L1-norm optimization.

Shengkai Guo1, Zihe Xu1, Xinyan Li1

  • 1Frontiers Science Center for Nonlinear Expectations (Ministry of Education), Research Center for Mathematics and Interdisciplinary Sciences; Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao 266237, China.

Ultramicroscopy
|May 6, 2025
PubMed
Summary
This summary is machine-generated.

This study introduces a new robust method for cryo-electron tomography (cryo-ET) alignment, improving projection parameter calibration by using L1-norm optimization under Laplace noise assumptions for more accurate results.

Keywords:
Cryo-ETFiducial marker-based alignmentL(1)-norm optimizationSmoothing approximation

More Related Videos

Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography
11:33

Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography

Published on: January 30, 2016

10.8K
Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

4.4K

Related Experiment Videos

Last Updated: May 9, 2025

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

4.7K
Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography
11:33

Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography

Published on: January 30, 2016

10.8K
Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

4.4K

Area of Science:

  • * Structural biology
  • * Biophysics
  • * Computational imaging

Background:

  • * Fiducial marker-based alignment is crucial for cryo-electron tomography (cryo-ET) image reconstruction.
  • * Accurate calibration of projection parameters is essential for high-resolution 3D models.
  • * Existing methods struggle with noise and outliers, often assuming incorrect noise distributions.

Purpose of the Study:

  • * To develop a more robust projection parameter calibration model for cryo-ET.
  • * To address limitations of current methods in handling noise and outliers.
  • * To improve the accuracy and reliability of cryo-ET alignment.

Main Methods:

  • * Proposed a novel robust calibration model using L1-norm optimization.
  • * Incorporated a Laplace noise assumption to better model real-world data.
  • * Developed a fast and stable first-order optimization method with smooth approximation.

Main Results:

  • * The L1-norm optimization model demonstrated superior robustness against noise and outliers.
  • * The proposed method achieved higher accuracy in simulated and real-world cryo-ET data.
  • * The new optimization technique improved computational speed and stability.

Conclusions:

  • * The L1-norm optimization under Laplace noise provides a more effective approach for cryo-ET projection parameter calibration.
  • * This method enhances the overall accuracy and reliability of cryo-ET reconstructions.
  • * The developed optimization strategy offers practical advantages for cryo-ET data processing.