Related Experiment Videos
Determination of polysorbate in ascites fluid from a premature infant
Journal of Analytical Toxicology
|July 1, 1985
Insights
A new method detects poly(oxy-1,2-ethanediyl) oligomers in body fluids. High levels of these compounds were found in infant peritoneal fluid after vitamin E supplementation.
Area of Science:
- Analytical Chemistry
- Biochemistry
- Clinical Chemistry
Background:
- Poly(oxy-1,2-ethanediyl) oligomers, often used as surfactants, can be present in pharmaceutical formulations.
- Monitoring these compounds in biological samples is crucial for assessing patient safety, especially in vulnerable populations like neonates.
- Existing analytical methods may lack the sensitivity or specificity required for accurate quantification in complex matrices like body fluids.
Purpose of the Study:
- To develop and validate a sensitive method for determining poly(oxy-1,2-ethanediyl) oligomers in human body fluids.
- To investigate the presence and levels of these oligomers in peritoneal fluid of infants receiving vitamin E supplements.
Main Methods:
- Utilized ammonium cobaltothiocyanate complexation for selective binding of the target analytes.
- Employed high-pressure liquid chromatography (HPLC) for efficient separation of the oligomers.
- Applied visible spectrophotometry for sensitive and quantitative detection of the complexed oligomers.
Main Results:
- Successfully established a method for the determination of poly(oxy-1,2-ethanediyl) oligomers.
- Analysis of peritoneal fluid samples from an infant treated with E-ferol (vitamin E supplement) revealed significant levels of polysorbates.
- Detected concentrations reached up to 100 micrograms/mL, indicating substantial exposure.
Conclusions:
- The developed analytical method is effective for quantifying poly(oxy-1,2-ethanediyl) oligomers in body fluids.
- The findings highlight the potential for high systemic levels of these compounds following administration of certain vitamin E formulations.
- Further research is warranted to understand the clinical implications and long-term effects of such exposure in infants.
Abstract:
A method is described for the determination of poly(oxy-1,2-ethanediyl)oligomers in body fluids using ammonium cobaltothiocyanate complexation in conjunction with high pressure liquid chromatography and visible spectrophotometry. Analysis of peritoneal fluid from a baby given E-ferol, a vitamin E supplement, revealed levels as high as 100 micrograms/mL polysorbate.